ALLIED TELESYN, INC.
AT-125, AT-126
Card Type | Transceiver |
NIC Type | Ethernet |
Network Transfer Rate | 10Mbps |
Topology | Linear Bus, Star |
Wiring Type | AUI transceiver via DB-15 port Fiber optic cable |
Data Bus | None |

CONNECTIONS | |||
Function | Label | Function | Label |
Fiber optic connector - receive | CN1 | AUI connector | CN3 |
Fiber optic connector - transmit | CN2 | ||
USER CONFIGURABLE SETTINGS | |||
Function | Label | Position | |
| » | SQE/Heartbeat switch disabled | SW1/1 | On |
SQE/Heartbeat switch enabled | SW1/1 | Off | |
| » | Continuous transmit function disabled | SW1/2 | On |
Continuous transmit function enabled | SW1/2 | Off | |
| » | Link test function - always on | SW1/3 | On |
| » | Factory configured - do not alter | SW1/4 | On |
TRANSMIT POWER SELECTION | ||||||
Setting | JP1/A | JP1/B | JP1/C | JP2/A | JP2/B | JP2/C |
Low | Closed | Open | Open | Closed | Open | Open |
Medium | Open | Closed | Open | Open | Closed | Open |
High | Open | Open | Closed | Open | Open | Closed |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
Transmit | Unidentified | On | Data is being transmitted |
Transmit | Unidentified | Off | Data is not being transmitted |
Receive | Unidentified | On | Data is being received |
Receive | Unidentified | Off | Data is not being received |
Collision | Unidentified | On | Collision detected on network |
Collision | Unidentified | Off | No collision detected on network |
Link status | Unidentified | On | Link test function is disabled |
Link status | Unidentified | Off | Link test function is enabled |
Power/SQE test | Yellow | On | SQE/Heartbeat test is enabled |
Power/SQE test | Green | On | SQE/Heartbeat test is disabled |