ANCO TECHNOLOGY, INC.
E5001
NIC Type | Ethernet |
Transfer Rate | 10Mbps |
Data Bus | 8-bit ISA |
Topology | Star |
Wiring Type | Unshielded twisted pair AUI transceiver via DB-15 port |
Boot ROM | Available |

INTERRUPT REQUEST | ||||||
IRQ | JP1A | JP1B | JP1C | JP1D | JP1E | |
2/9 | Closed | Open | Open | Open | Open | |
| » | 3 | Open | Closed | Open | Open | Open |
6 | Open | Open | Closed | Open | Open | |
6 | Open | Open | Open | Closed | Open | |
7 | Open | Open | Open | Open | Closed | |
CABLE TYPE | ||
Type | SW1/1 | |
| » | Unshielded twisted pair | On |
AUI transceiver via DB-15 port | Off | |
LINK INTEGRITY TEST | ||
Setting | JP31 | |
| » | Enabled | Pins 1 & 2 Closed |
Disabled | Pins 2 & 3 Closed | |
Note:Link Integrity is only used with 10Base-T wiring. When using an AUI transciever, the test should be disabled. | ||
I/O BASE ADDRESS | |||
Address | SW1/3 | SW1/4 | |
| » | 300-31Fh | On | On |
320-33Fh | Off | On | |
340-35Fh | On | Off | |
360-37Fh | Off | Off | |
BOOT ROM ADDRESS | ||||
Address | SW1/5 | SW1/6 | SW1/7 | SW1/8 |
Disabled | Off | Off | Off | Off |
C4000h | On | On | On | Off |
C8000h | Off | On | On | Off |
CC000h | On | Off | On | Off |
D0000h | Off | Off | On | Off |
D4000h | On | On | Off | Off |
D8000h | Off | On | Off | Off |
DC000h | On | Off | Off | Off |
DIAGNOSTIC LED(S) | |||
LED | Link Integrity | Status | Condition |
LED1 | Enabled | On | Twisted pair network connection good |
LED1 | Enabled | Off | Twisted pair network connection broken |
LED1 | Disabled | On | Data is being received power |
LED1 | Disabled | Off | Data is not being received power |
Note:The condition shown by LED1 depends on the setting of the link integrity test switch SW1/2. (see above) | |||